composite deck fire rate es report

Fire Resistance Assembly Chart Fire Resistance

1. UL tests rate an entire assembly. No ceiling or suspension system product alone constitutes a fire-rated assembly. 2. You can use only the specific type size and minimum thickness of Fire Guard™ ceilings or suspension system identified in each assembly. 3. This table is a guide. (See UL Fire Resistance Directory for complete design details).

Get Price

Toris - EPIC Metals

Toris Roof Deck Ceiling Systems are designed and engineered to span long distances up to 30 feet depending on the project requirements. Toris 7 (7” depth) can span up to 30 feet while Toris 5.5 (5.5” depth) spans up to 27 feet Toris 4 (4” depth) spans up to 24 feet and Toris can span up to 18 feet (2.5” depth).

Get Price

Cross-Laminated Timber (CLT) - APA – The Engineered Wood

ANSI/APA PRG 320 Standard for Performance-Rated Cross-Laminated Timber Provides requirements and test methods for qualification and quality assurance for performance-rated CLT which is manufactured from solid-sawn lumber or structural composite lumber.

Get Price

Flame Shield - ModWood

Flame Shield® is a specially formulated ModWood with a fire retardant additive included. Flame Shield® can be used in bushfire rated areas of BAL-12.5 BAL-19 BAL-29 and BAL-40. Flame Shield® has the highest BAL rating compared to other timber based decking in the Australian market place.

Get Price

Technical & Safety Information - Armadillo Deck Composite Decking

Store for long periods of time flat with support every 2 feet. Do not attempt to lift similar volumes of Armadillo composite decking boards as if they were wood. Documentation for Armadillo Composite Decking Armadillo California Fire Report – Wildland Urban Interface (W.U.I) Armadillo ICC-ES Report – updated March 2020 Armadillo End Sealer

Get Price

Literature – Verco Deck

Floor Deck Composite. IAPMO ES Evaluation Report ER-0217 – IAPMO ES Evaluation Report (2015 2012 & 2009 IBC / 2016 CBC / LARR – LABC 2017) Revised 27 Dec 2018.

Get Price

Most Widely Acceepted and Trusted

5.3 The use of the deck boards as components of a fire-resistance-rated assembly is outside the scope of this report. 5.4 The compatibility of the fasteners with the supporting construction including chemically treated wood is outside the scope of this report. 5.5 Deck boards must be directly fastened to supporting construction.

Get Price

W3 Formlok: Verco Floor Deck | 3" Deep | Metaldeck.com

FORMLOK composite slabs may be used to meet hourly fire ratings. The type and thickness of concrete specified will determine whether fireproofing will be required on the underside of the FORMLOK deck. Typically 2½ in. of concrete over the top of the deck is required for fire ratings with fireproofing on the underside of the deck.

Get Price

The Most Fire-Resistant Decking: Composites vs. Seven Trust - TimberTown

The first test was the open flame test. For this test we placed each of the boards facedown on the fire pit and then we stoked the fire as hot as we could get it well above 650 degrees Fahrenheit! We kept the boards on the fire pit for 15-20 seconds and then took them out to see if they had caught of fire. First was the Cedar board.

Get Price

ICC-ES Evaluation Report ESR-1190

152 mm) composite lumber when used as a stair tread is satisfactory to resist the code-prescribed concentrated load of 300 lbf (1.33 kN) when installed at a maximum center-to-center spacing in accordance with Table 4. 5.0 CONDITIONS OF USE The Seven Trust Deck Boards Seven Trust Rail Assembly and Seven Trust Designer Rail Assembly described in this report comply

Get Price

ICC ES Report ESR - California Cascade

5.3 The use of the deck boards as components of a fire-resistance-rated assembly is outside the scope of this report. 5.4 The compatibility of the fasteners with the supporting construction including chemically treated wood is outside the scope of this report. 5.5 Deck boards must be directly fastened to supporting construction.

Get Price

Canam - Steel Deck Catalogue (Canada)

The P-3615 P-3606 P-3623 and P-2432 deck profiles are available with embossments to act in composite action with a concrete slab. Tables for these composite sections show loads and unshored spans for normal weight concrete and light weight concrete on separate pages. The P-3615 P-3606 P-2436 and P-2404 deck profiles are

Get Price

UL Evaluation Report - Owens Corning

For roof slopes greater than 4:12 (33.33% slope or 18º) the roof deck must be covered with a minimum of one layer of underlayment as described in Sections 7.2 and 7.3 of this Report. Underlayment application must be in accordance with Section 1507.2.8of the 2015 2012 2009

Get Price

UL Evaluation Report - GAF

Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction FM 4474-2011 Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures ICC ES Acceptance Criteria for Membrane Roof-Covering Systems (AC75) Dated July 2010

Get Price

Table 1: Unprotected Fire Resistance Rating - Metal Deck

8 VF5 VERCO DECKING INC. www.vercodeck.com Fire-Rated Composite Slabs FORMLOK composite slabs may be used to meet hourly fire ratings. The type and thickness of concrete specified will determine whether fireproofing will be required on the underside of the FORMLOK deck. Typically 2½ in. of concrete over the top of the deck is required for fire

Get Price

Design of composite steel deck floors for fire

For Eurocode design BS EN 1994-1-2 contains a simplified method for calculating the design moment of resistance of composite steel deck floors in fire. It should be noted that in the National Annex Informative Annex D Model for the calculation of the fire resistance of unprotected composite slabs exposed to fire beneath the slab according to the standard temperature-time curve is not

Get Price

Report ESR 3168 - Seven Trust

composite decking and fascia as a component of a fire-resistance-rated assembly is outside the scope of this report. 5.5 . The compatibility of the fasteners with the supporting construction including chemically treated wood is outside the scope of this report. 5.6 . The deck boards must be directly fastened to supporting construction.

Get Price

WUI Approved / Class A Fire Rated Decking and Siding

WUI Approved & Class A Fire Rated Decking and Siding Seven TrustXTR has been Tested and Meet Standards for Class A Fire Rated and W.U.I. Approved for both our Decking & Siding. Seven TrustXTR Fused Bamboo Decking & Siding has been tested for flame smoke and fire testing and has earned the Class A fire rating.

Get Price

ICC-ES Evaluation Report ESR-2053 - GAF

VersaShield® Fire-Resistant Roof Deck Protection have the roof classification specified in Table 1. The roof coverings must be recognized in a current ICC-ES evaluation report as shown in Table 2. 5.0 CONDITIONS OF USE The VersaShield® Fire-Resistant Roof Deck Protection described in this report complies with or is a suitable

Get Price

SECTION 05311 - EPICORE MSR COMPOSITE FLOOR DECK SYSTEM PART

B. Epicore MSR Composite floor deck panels shall be elevated above the ground sloped to provide Proj. No. 11075 Epicore MSR – Composite Floor Deck System 05311 - 2 drainage and if required protected from weather with a ventilated covering.

Get Price

LONG-SPAN COMPOSITE SYSTEMS Featuring Versa-Dek Composite

Composite is a versatile long-span composite ® floor system. It’s ‘dovetail’ profiling keys to concrete to create a superior composite bond. Because more concrete is placed in the bottom of the deck the total slab thickness needed to achieve fire ratings is the shallowest available. Versa-Dek®

Get Price

Fire Resistant Deck Material: Wood and Composite Decking

Most composite decking manufacturers have fire testing

Evaluation Reports Program - ICC Evaluation Service LLC (ICC-ES)

PLEASE NOTE: All of the evaluation reports that may be downloaded from this web site are valid although some have re-examination dates that have passed. In the case of the latter the reports are currently undergoing re-examination as required by ICC-ES Rules of Procedure; or they may be legacy reports whose term has been extended without a change to the re-examination date.

Get Price

Tech Specs - Decking | Composite Timber | PermaTimber®

Welcome to PermaTimber® by Perma Composites® - a suite of high performance eco-friendly composite timber products produced from 87% recycled materials. Resources Brochures

Get Price

ICC-ES Evaluation Report ESR-1735P

figures dated March 1 2011 is part of this report. Section properties and minimum design base-metal thicknesses are shown in Table 4 and deck profiles are shown in Figure 3. Allowable reactions based on web crippling are shown in Table 5 and are applicable to bare deck panels and to concrete-filled composite deck panels during the

Get Price

Code Compliance Research Report CCRR-0128

ICC-ES AC174 Acceptance Criteria for Deck Board Span Ratings and Guardrail Systems (Guards and Handrails) revised December 2014. 7.3. Reports of testing demonstrating compliance with ICC-ES AC109 Acceptance Criteria for Thermoplastic Composite Lumber Products effective July 1 2006.

Get Price

FLOOR DECK DESIGN GUIDE - ASC Steel Deck

Gray cells are based on 1 hour and 2 hour fire ratings with 20 and 18 gauge decks Panel Features and Benefits 1.1 6 V1.0 • Composite and Non-Composite Design Guide www.ascsd.com

Get Price

Balcony fire regulations - everything you need to know about

In terms of balcony specification one of the most obvious implications is a narrowing of options for decking and flooring materials. A number of materials with elements of wood including composite decking products were previously compliant but are no longer permissible as they are not A2-s1 d0 rated or class A1 under the Euroclass system.

Get Price

Product Details

Product List